2

Over the weekend, I got several emails from our network storage server (just a custom box with CentOS 5 and 2 2tb drives software raid 1) indicating SMART detected issues with one of the drives.

I did a status and 2 of the raided partitions were marked failed:

    [root@aapsan01 ~]# cat /proc/mdstat
Personalities : [raid1]
md1 : active raid1 sdb1[1] sda1[0]
      104320 blocks [2/2] [UU]

md0 : active raid1 sdb3[1] sda3[2](F)
      4064320 blocks [2/1] [_U]

md3 : active raid1 sdb5[1] sda5[0]
      1928860160 blocks [2/2] [UU]

md2 : active raid1 sdb2[1] sda2[2](F)
      20482752 blocks [2/1] [_U]

So, I set all sda's partitions to "failed," removed all sda mirrors successfully, put a brand new 2tb identical drive in (after shutdown) and booted. Now, I cannot reach the login because error messages keep repeating after md: autodetect raid array is reached during the boot process. At first the errors were something like:

  DRDY err (UNC) -- exception emask media error

Now I get I/O errors. I tried with the corrupt drive removed and then with it in again. Same show. The write ups I've found show this to be a simple recovery process. What gives? Anyone encounter anything similar? It appears as though the boot process is still continuing, though it's taking eons to go through each step. Has anyone ever had to wait so long to reach the prompt? Hopefully, if I can't get to the prompt I can get somewhere with the rescue cd.

3
  • 1
    Isn't it some sdb partitions that have failed?
    – Linker3000
    Dec 6, 2010 at 19:37
  • How can you tell from the stat message? The email I got from the mdadm daemon said "It could be related to component device /dev/sda3." Dec 6, 2010 at 21:01
  • Look at md2 - it has two partitions in the array listed in order [sdb2] [sda2] and the status of the pair is listed as [_U], which means that the first partition ([sdb2]) has dropped out of the pairing. Have a read here: howtoforge.com/replacing_hard_disks_in_a_raid1_array
    – Linker3000
    Dec 6, 2010 at 23:03

3 Answers 3

1

Look at md2 - it has two partitions in the array listed in order [sdb2] [sda2] and the status of the pair is listed as [_U], which means that the first partition ([sdb2]) has dropped out of the pairing. Have a read here: http://www.howtoforge.com/replacing_hard_disks_in_a_raid1_array. Hope you get it sorted.

1
  • That is very helpful. I've seen write ups all over the web on it, but nowhere can I remember anyone stating for certain that the underscore side indicates the bad one. It probably should be intuitive but I guess I've been in sort of a panic mode and it didn't sink in. Thanks. Dec 7, 2010 at 15:59
0

I'm a dummy. I had misidentified the failing disk and was trying to use the bad one in my recovery effort. For anyone interested, you can use lshal to get the s/n of the bad drive. redirect lshal's output to a log file and then search for sda sdb or whatever mdadm or SMART identified as being bad.

0

Following on on Linker3000's answer, the contents of the disk you removed first should still be ok. Remove the disk that you now know is actually the broken one and try starting with the good disk alone. There is a small chance that md marked your healthy disk as being behind when you re-added it with the broken disk present. In this case, you need to start from a live CD/USB and re-activate your RAID. Once you have your system running ok, you can start again with the normal steps to add a new disk to your RAID 1s.